Nitrile Gloves

No. 1 in Nitrile

Nitrile Gloves

Hartalega has pioneered the production of Nitrile gloves with over a decade of delivering major technological improvements, and an unmatched quality standard.

Nitrile

Nitrile Powder Free 2.5 Mil

Regulatory Compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
Standards
ASTM D6319, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
Classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
Application Settings
Low risk - medical, dental, patient care, age care, pathology lab, police enforcement & food handling
Colour
Violet blue, white
glove_length
≥ 230
palm_thickness
≥ 0.07 ± 0.02
finger_thickness
0.09 ± 0.02
tensile_stength_before_aging
≥ 18.0
tensile_strength_after_aging
≥ 16
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
≥ 240
median_palm_thickness
0.07 ± 0.02
median_finger_thicknes
0.09 ± 0.02
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
application_settings
Low risk - medical, dental, patient care, age care, pathology lab, police enforcement & food handling
product_regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, EC 1935/2004, PPE 89/686/EEC
product_standards
ASTM D6319, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
product_classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
product_application_settings
Low risk - medical, dental, patient care, aged care, pathology lab, police enforcement and food handling
product_colour
Violet blue, white
testing_machine_1
ASTM D6319
testing_machine_2
EN 455
tensile_strength_before_aging
≥ 18
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min 240 245
Palm Thickness (mm) 0.07 ± 0.02 0.07
Finger Thickness (mm) 0.09 ± 0.02 0.11
Physical Properties Specification Typical Value
  Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 6.8 N 7.7 N
Tensile Strengh (ASTM D6319) ≥ 14 MPa ≥ 14 MPa 27.9 MPa 25.5 MPa
Elongation (ASTM D6319) ≥ 500% ≥ 400% 537% 453%

Nitrile Powder Free 3.2 Mil

Regulatory Compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
Standards
ASTM D6319, ASTM D6978, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
Classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
Application Settings
Medium risk - medical, dental, procedures, chemotherapy drugs handling, pathology lab, patient care & food handling
Colour
Aqua blue
glove_length
≥ 230
palm_thickness
0.08 ± 0.02
finger_thickness
0.11 ± 0.02
tensile_stength_before_aging
0
tensile_strength_after_aging
≥ 16
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
≥ 240
median_palm_thickness
0.08 ± 0.02
median_finger_thicknes
0.11 ± 0.02
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
product_regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, EC 1935/2004, PPE 89/686/EEC
product_standards
ASTM D6319, ASTM 6978, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
product_classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
product_application_settings
Medium risk - medical, dental, procedures, chemotherapy drugs, pathology lab, patient care and food handling
product_colour
Aqua blue
testing_machine_1
ASTM D6319
testing_machine_2
EN 455
tensile_strength_before_aging
≥ 18
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min 240 250
Palm Thickness (mm) 0.08 ± 0.02 0.08
Finger Thickness (mm) 0.11 ± 0.02 0.11
Physical Properties Specification Typical Value
  Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 6.8 N 6.4 N
Tensile Strengh (ASTM D6319) ≥ 18 MPa ≥ 16 MPa 26.3 MPa 24.6 MPa
Elongation (ASTM D6319) ≥ 500% ≥ 400% 561% 475%

Nitrile Powder Free 3.5 Mil

Regulatory Compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
Standards
ASTM D6319, ASTM D6978, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
Classification
Class I (FDA), Class I (MDD 93/42/EEC), *Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
Application Settings
Medium risk - medical, dental, procedures, chemotherapy drugs handling, pathology lab, patient care, veterinary & food handling
Colour
Aqua blue, white
testing_machine_1
ASTM D6319
testing_machine_2
EN 455
glove_length
≥ 230
palm_thickness
0.09 ± 0.02
finger_thickness
0.12 ± 0.02
tensile_strength_before_aging
≥ 18
tensile_strength_after_aging
≥ 16
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
≥ 240
median_palm_thickness
0.09 ± 0.02
median_finger_thicknes
0.12 ± 0.02
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
product_regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, PPE 89/686/EEC
product_standards
ASTM D6319, ASTM 6978, EN455 part 1, 2, 3 & 4, EN 420, EN 374 part 1, 2 & 3
product_classification
Class I (FDA), Class I (MDD 93/42/EEC), Category III (PPE 89/686/EEC)
product_application_settings
Medium risk - medical, dental, procedures, chemotherapy drugs, pathology lab, patient care and food handling
product_colour
Aqua blue, white
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min 240 245
Palm Thickness (mm) 0.09 ± 0.02 0.09
Finger Thickness (mm) 0.12 ± 0.02 0.13
Physical Properties Specification Typical Value
  Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 9 N 9 N
Tensile Strengh (ASTM D6319) ≥ 18 MPa ≥ 16 MPa 32.1 MPa 31.6 MPa
Elongation (ASTM D6319) ≥ 500% ≥ 400% 524% 469%

Nitrile Powder Free 3.5 Mil Extended Cuff

Regulatory Compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC
Standards
ASTM D6319, ASTM 6978, EN455 part 1, 2, 3 & 4, ISO 11193 - 1
Classification
Class I (FDA), Class I (MDD 93/42/EEC)
Application Settings
High risk - first responder, paramedics & chemotherapy drugs handling, veterinary
Colour
Cobalt blue
testing_machine_1
ASTM D6319
testing_machine_2
EN 455
glove_length
290 ± 10
palm_thickness
0.10 ± 0.02
finger_thickness
0.13 ± 0.02
tensile_strength_before_aging
≥ 18
tensile_strength_after_aging
≥ 16
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
290 ± 10
median_palm_thickness
0.10 ± 0.02
median_finger_thicknes
0.13 ± 0.02
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
product_regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, EC 1935/ 2004
product_standards
ASTM D6319, ASTM 6978, EN455 part 1, 2, 3 & 4, ISO11193-1, EN 1186, EN 13130, CEN/ TS 14234
product_classification
Class I (FDA), Class I (MDD 93/42/EEC), Category III (BfR XXI)
product_application_settings
High risk - first responder, paramedics, chemotherapy, drugs handling, veterinary and food handling
product_colour
Cobalt blue
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min. 280 292
Palm Thickness (mm) 0.09 ± 0.02 0.10
Finger Thickness (mm) 0.12 ± 0.02 0.14
Physical Properties Specification Typical Value
  Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 13.1 N 12.9 N
Tensile Strengh (ASTM D6319) ≥ 18 MPa ≥ 16 MPa 34.0 MPa 34.7 MPa
Elongation (ASTM D6319) ≥ 500% ≥ 400% 524% 429%
Force At Break (ISO 11193 - 1) ≥ 7 N ≥ 6 N 15.1 N 15.2 N
Elongation (ISO 11193 - 1) ≥ 500% ≥ 400% 537% 452%

Nitrile Powder Free 8.0 Mil Extended Cuff

Regulatory Compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC
Standards
ASTM D6319, EN455 part 1, 2, 3 & 4
Classification
Class I (FDA), Class I (MDD 93/42/EEC)
Application Settings
High risk - sterilisation laboratories, controlled environment, semiconductor industry, electronic industry, mechanical industry, chemical industry, cleaning and maintenance.
Colour
Sky blue
testing_machine_1
ASTM D6319
testing_machine_2
EN 455
glove_length
≥ 280
palm_thickness
0.20 ± 0.04
finger_thickness
0.28 ± 0.04
tensile_strength_before_aging
≥ 18
tensile_strength_after_aging
≥ 16
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
≥ 280
median_palm_thickness
0.20 ± 0.04
median_finger_thicknes
0.28 ± 0.04
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
product_regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, PPE 89/686/EEC
product_standards
ASTM D6319, EN455 part 1, 2, 3 & 4, ISO 11193-1, EN 1186, EN 13130, CEN/TS 14234
product_classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
product_application_settings
High risk - sterilisation laboratories, controlled environment, electronic industry, mechanical industry, chemical industry, cleaning and maintenance.
product_colour
Sky blue
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min 280 289
Palm Thickness (mm) 0.20 ± 0.04 0.2
Finger Thickness (mm) 0.24 ± 0.04 0.24
Physical Properties Specification Typical Value
  Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 20.8 N 21.4 N
Tensile Strengh (ASTM D6319) ≥ 18 MPa ≥ 16 MPa 29.4 MPa 34.2 MPa
Elongation (ASTM D6319) ≥ 500% ≥ 400% 553% 530%
Force At Break (ISO 11193 - 1) ≥ 7 N ≥ 6 N 22.9 N 17.1 N
Elongation (ISO 11193 - 1) ≥ 500% ≥ 400% 541% 515%

COATS® Colloidal Oatmeal Coated Nitrile Powder Free 2.5 Mil

Regulatory Compliance
FDA 510(k)
Standards
ASTM D6319
Patent
Patent 6,953,582; Patent 6,630,152; Patent 6,423,328; Patent 6,274,154; Patent 7,691,436; Patent 7,718,240; Patent 7,740,622; Patent 8,075,965
Colloidal Oatmeal Content
≥ 5 mg/glove
Application Settings
Medium risk - medical, dental, procedures, patient care, age care, beauty.
Colour
White, dawn blue
testing_machine_1
ASTM D3578
testing_machine_2
EN 455
glove_length
≥ 230
palm_thickness
0.07 ± 0.02
finger_thickness
0.09 ± 0.02
tensile_strength_before_aging
≥ 18.0
tensile_strength_after_aging
≥ 16.0
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
≥ 240
median_palm_thickness
0.07 ± 0.02
median_finger_thicknes
0.09 ± 0.02
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
product_regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, EC 1935/2004, PPE 89/686/EEC
product_standards
ASTM D6319, ASTM 6978, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
product_classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
product_application_settings
Low risk - medical, dental, procedures, chemotherapy drugs, pathology lab and food handling. Coated with FDA recognised skin protectant. Clinically proven to help protect and moisturise your skin from dry and irritated skin from prolonged glove use and hand wash.
product_colour
Dawn blue, white
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
7,691,436; 7,718,240; 7,740,622; 8,075,965; 8,458,818
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min 240 243
Palm Thickness (mm) 0.07 ± 0.02 0.07
Finger Thickness (mm) 0.10 ± 0.02 0.11
Physical Properties Specification Typical Value
Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 8.1 N 7.37 N
Tensile Strengh (ASTM D3578) ≥ 18 MPa ≥ 16 MPa 30.0 MPa 29.1 MPa
Elongation (ASTM D3578) ≥ 500% ≥ 400% 558% 463%

Biodegradable Nitrile Powder Free 3.0 Mil

Regulatory Compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
Standards
ASTM D6319, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
Classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
Application Settings
Low risk - medical, dental, patient care, age care, pathology lab, police enforcement & food handling
Colour
Violet blue, white
glove_length
≥ 230
palm_thickness
0.07 ± 0.02
finger_thickness
0.10 ± 0.02
tensile_stength_before_aging
≥ 18.0
tensile_strength_after_aging
≥ 16
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
≥ 240
median_palm_thickness
0.07 ± 0.02
median_finger_thicknes
0.10 ± 0.02
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
application_settings
Low risk - medical, dental, patient care, age care, pathology lab, police enforcement & food handling
product_regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive
product_standards
EN 455-1,2,3, ASTM D6319, ASTM D5151, ASTM D412, 21 CFR 177.2600, ISO 10993-10, JFSL, EN 420, ISO 10993-10
product_classification
Class I (FDA), Class I (MDD 94/42/EEC), Category I (PPE 2016/426)
product_application_settings
Medium risk – medical, dental, procedures, chemotherapy drugs, pathology lab, patient care and food handling
product_colour
Violet blue
testing_machine_1
ASTM D6319
testing_machine_2
EN 455
tensile_strength_before_aging
≥ 18
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min 240 245
Palm Thickness (mm) 0.07 ± 0.02 0.07
Finger Thickness (mm) 0.09 ± 0.02 0.11
Physical Properties Specification Typical Value
Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 6.8 N 7.7 N
Tensile Strengh (ASTM D6319) ≥ 14 MPa ≥ 14 MPa 27.9 MPa 25.5 MPa
Elongation (ASTM D6319) ≥ 500% ≥ 400% 537% 453%

Metal Detectable Nitrile Powder Free 3.2 Mil

Regulatory Compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
Standards
ASTM D6319, EN455 part 1, 2, 3 & 4, EN 1186, EN 13130, CEN/TS 14234, EN 420, EN 374 part 1, 2 & 3
Classification
Class I (FDA), Class I (MDD 93/42/EEC), Category 3 (BfR XXI), Category III (PPE 89/686/EEC)
Application Settings
Low risk - medical, dental, patient care, age care, pathology lab, police enforcement & food handling
Colour
Violet blue, white
glove_length
≥ 230
palm_thickness
0.08 ± 0.02
finger_thickness
0.13 ± 0.03
tensile_stength_before_aging
≥ 18.0
tensile_strength_after_aging
≥ 16
elongation_before_aging
≥ 500
elongation_after_aging
≥ 400
median_glove_length
≥ 240
median_palm_thickness
0.08 ± 0.02
median_finger_thicknes
0.13 ± 0.03
median_force_at_break_before_aging
≥ 6
median_force_at_break_after_aging
≥ 6
regulatory_compliance
FDA 510(k), MDD 93/42/EEC, REACH, ROHS Directive 2002/95/EC, EC 10/2011, REGULATION (EC) No 1935/2004, EC 1935/2004, PPE 89/686/EEC
application_settings
Low risk - medical, dental, patient care, age care, pathology lab, police enforcement & food handling
product_regulatory_compliance
MDD 93/42/EEC, REACH, ROH, EC 1935/2004, EU 10/2011
product_standards
EN 455 part 1,2 & 3, ASTM D6319, ASTM D5151, ASTM D412, 21 CFR 177.2600, ISO 10993-10, JFSL, EN 1186, EN 13130, EN 420, ISO 10993-10
product_classification
Class I (FDA), Class I (MDD 94/42/EEC), Category I (PPE 2016/426)
product_application_settings
Medium risk – manufacturing industries including food, pharmaceutical, pet food, cosmetic and textile
product_colour
Black
testing_machine_1
ASTM D6319
testing_machine_2
EN 455
tensile_strength_before_aging
≥ 18
product_material
product_particle_count
product_colloidal_oatmeal_content
product_patent
product_protein_content
testing_machine_3
force_at_break_before_aging
force_at_break_after_aging
elongation_before_aging_3
elongation_after_aging_3
product_series
Nitrile
Physical Dimensions Specification Typical Value
Glove Length (mm) Min 240 245
Palm Thickness (mm) 0.07 ± 0.02 0.07
Finger Thickness (mm) 0.09 ± 0.02 0.11
Physical Properties Specification Typical Value
Before Aging After Aging Before Aging After Aging
Force At Break (EN 455 - 2) ≥ 6 N ≥ 6 N 6.8 N 7.7 N
Tensile Strengh (ASTM D6319) ≥ 14 MPa ≥ 14 MPa 27.9 MPa 25.5 MPa
Elongation (ASTM D6319) ≥ 500% ≥ 400% 537% 453%
Nitrile Powder Free 2.5 Mil

Nitrile Powder Free 2.5 Mil

Low risk - medical, dental, patient care, aged care, pathology lab, police enforcement and food handling

View Details View Product

Nitrile Powder Free 3.2 Mil

Nitrile Powder Free 3.2 Mil

Medium risk - medical, dental, procedures, chemotherapy drugs, pathology lab, patient care and food handling

View Details View Product

Nitrile Powder Free 3.5 Mil

Nitrile Powder Free 3.5 Mil

Medium risk - medical, dental, procedures, chemotherapy drugs, pathology lab, patient care and food handling

View Details View Product

Nitrile Powder Free 3.5 Mil Extended Cuff

Nitrile Powder Free 3.5 Mil Extended Cuff

High risk - first responder, paramedics, chemotherapy, drugs handling, veterinary and food handling

View Details View Product

Nitrile Powder Free 8.0 Mil Extended Cuff

Nitrile Powder Free 8.0 Mil Extended Cuff

High risk - sterilisation laboratories, controlled environment, electronic industry, mechanical industry, chemical industry, cleaning and maintenance.

View Details View Product

COATS® Colloidal Oatmeal Coated Nitrile Powder Free 2.5 Mil

COATS® Colloidal Oatmeal Coated Nitrile Powder Free 2.5 Mil

Low risk - medical, dental, procedures, chemotherapy drugs, pathology lab and food handling. Coated with FDA recognised skin protectant. Clinically proven to help protect and moisturise your skin from dry and irritated skin from prolonged glove use and hand wash.

View Details View Product

Biodegradable Nitrile Powder Free 3.0 Mil

Biodegradable Nitrile Powder Free 3.0 Mil

Medium risk – medical, dental, procedures, chemotherapy drugs, pathology lab, patient care and food handling

View Details View Product

Metal Detectable Nitrile Powder Free 3.2 Mil

Metal Detectable Nitrile Powder Free 3.2 Mil

Medium risk – manufacturing industries including food, pharmaceutical, pet food, cosmetic and textile

View Details View Product